COMPARATIVE ANALYSIS OF KIRLIANOGRAFIIA IMAGES GLOW OF BIOLOGICAL TISSUES WITH BIOCHEMICAL PROCESSES
DOI:
https://doi.org/10.11603/mie.1996-1960.2015.4.5444Abstract
Kirlian diagram samples Conducted. Achilles tendon dead people with various postmorbidnym period (from 5:0 until 22 days) and optoelectronics is part of the standard terms of the x-ray film developer. The results obtained were compared with biochemical indicators of the level of enzymes and content of degradation products of proteins, trace elements, derived fromthe investigated samples. For kirlianograficeskih studies used an experimental device, RIVERS 1, developed by Ukrainian Scientific Research Institute of mechanical engineering technologies (Dnepropetrovsk). For mathematical processing of results using Matlab program.
The growing shortage of ATP causes the breach and termination of ion exchange, increases reactive oxygen generation, lipid peroxidation destroys cell membranes. The process of self digestion (autoliza) tissue tendons, as shown by the results of the experiments, had cyclical changes metabolism enzyme activity (ALT), carbohydrate (LDH), nucleotides, of total protein and micronutrients.
References
Корреляция кирлианографических и биохимических характеристик на примере Ахиллового сухожилия / Н. М. Евдокименко, Л. А. Песоцкая, В. А. Повстяный, Н. В. Глухова // Валеологія: сучасний стан, напрямки та перспективи розвитку : тези допов. ХІІІ міжнар. наук.-практ. конф., 9-11 квітня 2015 р. - Харків, 2015. - Режим доступу: http://valeolog.net.
Песоцкая Л. А. О некоторых биохимических аспектах кирлианографии / Л. А. Песоцкая, Н. М. Евдокименко // Медицина: достижения нового века : матер. IV науч.-практ. конф. с междунар. уч., 27-28 февраля 2015 г., Гоа, Индия. - Академический журнал Западной Сибири. - 2015. - Т. 11, № 1 (56). - С. 17-18. - Режим доступу: www.elibrary.ru.
Mandel P. Energetishe Terminalpunkt / P. Mandel. -Diagnos-FRG : ESSEN, 1983. - 199 p.
Yuxin L. Image feature extraction and segmentation using fractal dimension / L. Yuxin, L. Yanda / IEEE. - 2007. - Vol. 2. - P. 975-979.
Long M. A Box-counting method with adaptable box height for
measuring the fractal feature of images / M. Long, F. Peng // Radioengeneering. - 2013. - Vol. 22, № 1. -P. 208-213.
Downloads
Published
How to Cite
Issue
Section
License
Journal Medical Informatics and Engineering allows the author(s) to hold the copyright without registration
The majority of Medical Informatics and Engineering Open Access journals publish open access articles under the terms of the Creative Commons Attribution (CC BY) License which permits use, distribution and reproduction in any medium, provided the original work is properly cited. The remaining journals offer a choice of licenses.
This journal is available through Creative Commons (CC) License CC-BY 4.0