Clinical and morphological features of multi-point and linear colon electrically welded anastomosis

Authors

  • S. S. Podpriatov Clinical Research Centre of Bonding/Welding Surgery and New Surgical Technologies, Kyiv, Ukraine Kyiv Municipal Hospital Clinic No.Kyiv, Ukraine P. Shupyk National Medical Academy of Postgraduate Education, Ukraine
  • S. E. Podpryatov Clinical Research Centre of Bonding/Welding Surgery and New Surgical Technologies, Kyiv, Ukraine Kyiv Municipal Hospital Clinic No.Kyiv, Ukraine E. Paton Electric Welding Institute of National Academy of Science, Ukraine
  • S. G. Gichka Bogomolets National Medical University image/svg+xml
  • A. V. Makarov P. Shupyk National Medical Academy of Postgraduate Education, Ukraine
  • G. S. Marinsky E. Paton Electric Welding Institute of National Academy of Science, Ukraine
  • V. A. Tkachenko E. Paton Electric Welding Institute of National Academy of Science, Ukraine
  • S. V. Tkachenko E. Paton Electric Welding Institute of National Academy of Science, Ukraine
  • O. V. Chernets E. Paton Electric Welding Institute of National Academy of Science, Ukraine
  • D. V. Tarnavsky National University of Life and Environmental Sciences of Ukraine image/svg+xml

DOI:

https://doi.org/10.11603/2414-4533.2018.3.9229

Keywords:

anastomosis, colon, electric welding, radio frequency, instrument, bursting pressure, morphology

Abstract

The aim of the work: to study the influence onto clinical hermetic rupture properties the morphological transformations types inside the colon tissues during electrically welded anastomosis creation using linear or multi-point applying methods and various pressure characteristics of the instrument.

Materials and Methods. The swine colon sections 31 cm in diameter, were anastomosed in end-to-end way during acute experiment. There were 2 double-line stapled and 144 electro-welded anastomoses: 48 multy-point, made by toothed tweezers with a topical pressure of 1.8 N/mm2), and 56 linear circular (pressure 2.1 N/mm2 or 3.0 N/mm2).

The electric welding device "Patonmed" EKVZ-300 (440 kHz) was used. Anastomoses were tested by a slow liquid injection into closed section, up to 15 mm Hg/min. The 3 types electro-welding connections were divided by blind method to the injection groups. The first group injected up to 24.5 mm Hg. – the pressure of liquid outflow have established for stapled anastomoses. The second group was ruptured. Anastomoses then were sent for histological examination.

Results and Discussion. All welded anastomoses remained sealed at a bursting pressure 23.5 mm Hg, and reached a break: multi-point at (37.2±5.2) mm Hg. linear – (created under pressure of 2.1 N mm2) (53.6±9.8) mm Hg, linear (created under pressure 3.0 N/mm2) – (62.8±6.2) mm Hg. The linear anastomoses compound thickness varied from 0.1 to 0.3 mm, and differed slightly in morphological characteristics in 1/3 of its circumference segment, where a large proportion of the lacunas and the number of intervals between the merged coagulated muscle layers were found. The rupture occurred in such segment. Although the integrity of the welding coagulation changes along the anastomoses circumference was preserved. The density of the 3.0 N/mm2-created anastomosis was achieved by lover gaps number and wider layers merging inside the conglomerate. The multi-point anastomosis thickness fluctuated from 1.8 mm to 5 mm in regular. At the point of jagged electrodes edges have convergenced, the merge between the muscle layers were established, the cell fragments and fibers became orientated, and the bond conglomerate was formed. Nearby muscular layers did not merge as topical, although they are involved into coagulation conglomerate, which comprises the muscular and submucosal layers mainly. Serous layers were merged also.

Author Biographies

  • S. S. Podpriatov, Clinical Research Centre of Bonding/Welding Surgery and New Surgical Technologies, Kyiv, Ukraine Kyiv Municipal Hospital Clinic No.Kyiv, Ukraine P. Shupyk National Medical Academy of Postgraduate Education, Ukraine

    лікар-хірург-проктолог

  • S. E. Podpryatov, Clinical Research Centre of Bonding/Welding Surgery and New Surgical Technologies, Kyiv, Ukraine Kyiv Municipal Hospital Clinic No.Kyiv, Ukraine E. Paton Electric Welding Institute of National Academy of Science, Ukraine

    Київський центр електрозварювальної хірургії та новітніх технологій,
    Київська міська клінічна лікарня №1

References

Shogan, B.D., Belogortseva, N., Luong, P.M., Zaborin, A., Lax, S., Bethel, C., … Alverdy, J.C. (2015). Collagen degradation and MMP9 activation by Enterococcus faecalis contribute to intestinal anastomotic leak. Sci. Transl. Med., 7, 286ra, 68-68. doi: 10.1126/scitranslmed.3010658.

Yegorov, V.I., Schastlivtsev, I.V., Turusov, R.A. & Baranov, A.O. (2002). Mekhanicheskiye narusheniya pod nityu kishechnogo shva kak prichina narusheniy mikrotsirkulyatsii v oblasti soustiy [Mechanical abnormalities under the filament of the intestinal suture as a cause of microcirculation disorders in the region of anastomosis]. Annaly khirurgii – Annals of Surgery, 3, 66-68 [in Russian].

Neutzling, C.B., Lustosa, S.A.S., Proenca, I.M., da Silva, E.M.K. & Matos, D. (2012). Stapled versus handsewn methods for colorectal anastomosis surgery. Matos D. (Ed.). Cochrane Database Syst. Rev., 2. DOI: 10.1002/14651858.CD003144.pub2.

de Hingh, I.H., de Man, B.M., Lomme, R.M., van Goor, H. & Hendriks, T. (2003). Colonic anastomotic strength and matrix metalloproteinase activity in an experimental model of bacterial peritonitis. Br. J. Surg., 90, 981-988. doi.org/10.1002/bjs.4146

Ballantyne, G.H. (1983). Intestinal suturing. Review of the experimental foundations for traditional doctrines. Dis. Colon Rectum., 26 (12), 836-843. doi.org/10.1007/BF02554767

Pasic, F. & Salkic, N.N. (2013). Predictive score for anastomotic leakage after elective colorectal cancer surgery: a decision making tool for choice of protective measures. Surg. Endosc., 27, 3877-3882. doi: 10.1007/s00464-013-2997-1

Beard, J.D., Nicholson, M.L., Sayers, R.D., Lloyd, D. & Everson, N.W. (1990). Intraoperative air testing of colorectal anastomoses: a prospective, randomized trial. Br. J. Surg., 77 (10), 1095-1097. doi.org/10.1002/bjs.1800771006

Hendriks, T. & Mastboom, W.J. (1990). Healing of experimental intestinal anastomoses. Parameters for repair. Review Dis. Colon Rectum., 33 (10), 891-901. https://doi.org/10.1007/BF02051930

Bosmans, J.W.A.M., Jongen, A.C.H.M., Bouvy, N.D. & Derikx, J.P.M. (2015). Colorectal anastomotic healing: why the biological processes that lead to anastomotic leakage should be revealed prior to conducting intervention studies. BMC Gastroenterology., 15, 180. doi:10.1186/s12876-015-0410-3.

Paton, B.E. & Ivanova, O.M. (Eds.) (2009). Tkanevaya vysokochastotnaya elektrosvarochnaya khirurgiya [The live tissue’s high-frequency electric welding surgery]. Athlas. Kyiv: Naukova Dumka [in Russian].

Donskov, A.B., Donskov, A.B., Yesipov, V.K. & Kagan, I.I. (2011). Primeneniye mikrokhirurgicheskogo kishechnogo shva v usloviyakh peritonita pri povrezhdenii obodochnoy kishki [Application of microsurgical intestinal suture in conditions of peritonitis with damage to the colon]. Acta Biomedica Scientifica, (4-2), 234-236 [in Russian]. https://cyberleninka.ru/article/n/primenenie-mikrohirurgicheskogo-kishechnogo-shva-v-usloviyah-peritonita-pri-povrezhdenii-obodochnoy-kishki

Ho, Y.-H. & Ashour, M.A.T. (2010). Techniques for colorectal anastomosis. World J. Gastroenterol., 7, 16 (13), 1610-1621. doi: 10.3748/wjg.v16.i13.1610

Podpriatov, S.S., Podpriatov, S.E., Marinskyi, H.S., Chernets, O.V., Tkachenko, V.A., Byelousov, … Serdyuk, V.K. (2017). Modelne eksperymentalne doslidzhennia mekhanichnoi rezystentnosti stinky kyshky liudyny pid tyskom v prototypi elektrozvariuvalnoho instrumentu [Model experimental research of human intestine walls mechanical resistance under the pressure inside biologic welding instrument prototype]. Problemy viiskovoi okhorony zdorovia – Military Health Problems, (2), 325-331 [in Ukrainian].

Published

2018-10-16

Issue

Section

Experimental investigations

How to Cite

Clinical and morphological features of multi-point and linear colon electrically welded anastomosis. (2018). Hospital Surgery. Journal Named by L.Ya. Kovalchuk, 3, 50-56. https://doi.org/10.11603/2414-4533.2018.3.9229